Server Technology CWG-24V5Z458A9 Switched CDU

ServerTech ServerTech

New

The Switched CDU combines network configuration and management with power distribution, environmental monitoring and the ability to provide power monitoring per an individual outlet/device.  Power information per outlet includes current, voltage, power (kW), apparent power (VA), crest factor and power factor.  Reboot a single or dual-power server with one command. Receive SNMP or email-based alerts when power or environmental conditions exceed thresholds. Assign user specific access rights to designated outlets or groups.


Call For Price And Availability

India: +91 895 697 6186
USA: +1 510 651 2205
Singapore: +65 9152 4003

[email protected]

The Switched CDU combines network configuration and management with power distribution, environmental monitoring and the ability to provide power monitoring per an individual outlet/device.  Power information per outlet includes current, voltage, power (kW), apparent power (VA), crest factor and power factor.  Reboot a single or dual-power server with one command. Receive SNMP or email-based alerts when power or environmental conditions exceed thresholds. Assign user specific access rights to designated outlets or groups.

This Switched CDU has top entry for network, serial & environmental connections combined with a bottom power cord entry. Current monitors are easily inverted via the web GUI or serial interface.  This provides flexibility when connecting Switched CDU’s to overhead power or busways.

High Density:
Single-power input feed; 24 outlets per enclosure (Qty 12 IEC C13 & 12 IEC C19 outlets).

Power Distribution:
240/415V 3-phase, 20/30A power input feed option with 240V output.

Input Current Monitor:
Precisely measure the aggregate current draw (in amps) of each phase of the circuit.  On-site verification of the input current with LED digital display.  Remote verification via web browser or serial screen.
 
Networked Power Management:
Power cycle individual power outlets, or groups of power outlets, to remotely reboot servers and network devices, anywhere in the world.  Or, power-off unused power receptacles.

IP Access & Security:
Web interface, SSL, SSH, Telnet, SNMP, FTP, SNTP, Syslog, LDAP, LDAPS, TACACS, RADIUS, and RS-232 access.

SNMP Traps and Email alerts:
Provide automated alerts for power and environmental conditions.

Environmental Monitoring:
Each Switched CDU supports two external temperature & humidity probes and reports conditions through the user interface without the need for additional IP addresses.
 
Add an Expansion Module:
Daisy chain the Switched CDU Expansion Module (CXG) for power monitoring of separate power circuits from a single IP address.

Sentry Cabinet PDU Specifications
Item # Available Input 
Voltages
Rated Amperage Available Input Cord Outlets Dimensions 
(L x W x D)
CWG-24V5 (12xC13 & 12xC19) - 415V 3Ph
CWG-24V53458A9
CXG-24V53458A9*

240/415V 3-Phase Wye, 50/60Hz

20 A IEC Red 6hr 3P+N+G Plug, 10'(3m), Top Cord Entry (12) IEC 60320/C13 
(12) IEC 60320/C19
1753 x 44.4 x 88.9 mm. 
[69.0 x 1.75 x 3.50 in.)
CWG-24V54458A9
CXG-24V54458A9*

240/415V 3-Phase Wye, 50/60Hz

30 A IEC Red 6hr 3P+N+G Plug, 10'(3m), Top Cord Entry (12) IEC 60320/C13 
(12) IEC 60320/C19
1753 x 44.4 x 88.9 mm. 
[69.0 x 1.75 x 3.50 in.)
CWG-24V5Z458A9
CXG-24V5Z458A9*

240/415V 3-Phase Wye, 50/60Hz

30 A NEMA L22-30P Plug, 10'(3m), Top Cord Entry (12) IEC 60320/C13 
(12) IEC 60320/C19
1753 x 44.4 x 88.9 mm. 
[69.0 x 1.75 x 3.50 in.)
* CXG refers to the Expansion Module

Part Code:

CWG-24V5Z458A9

Write a review

Server Technology CWG-24V5Z458A9 Switched CDU

Server Technology CWG-24V5Z458A9 Switched CDU

The Switched CDU combines network configuration and management with power distribution, environmental monitoring and the ability to provide power monitoring per an individual outlet/device.  Power information per outlet includes current, voltage, power (kW), apparent power (VA), crest factor and power factor.  Reboot a single or dual-power server with one command. Receive SNMP or email-based alerts when power or environmental conditions exceed thresholds. Assign user specific access rights to designated outlets or groups.