Server Technology EMTH-1-1 Environmental Monitor Control Unit

1 Review(s)
ServerTech ServerTech

New

Ever increasing densities of vertically racked servers conserve valuable door space in the data center, but the resulting power consumption and heat dissipation create new concerns for data center managers.  Environmental Monitoring, particularly temperature & humidity, is a must for any sensitive infrastructure. The most recent ASHRAE thermal guidelines suggests three measurement points in the equipment rack.


Call For Price And Availability

India: +91 895 697 6186
USA: +1 510 651 2205
Singapore: +65 9152 4003

[email protected]

Ever increasing densities of vertically racked servers conserve valuable door space in the data center, but the resulting power consumption and heat dissipation create new concerns for data center managers.  Environmental Monitoring, particularly temperature & humidity, is a must for any sensitive infrastructure. The most recent ASHRAE thermal guidelines suggests three measurement points in the equipment rack.

Server Technology Smart and Switched CDUs support two combination temperature/humidity probes on the Master
unit. Newer Expansion units support two additional sensors. If additional probes are required, the EMCU-1-1B Environmental Monitor provides additional inputs.

Each EMCU supports:
> 2 Additional temperature and humidity measurements
> Water sensor
> 4 Dry contact closure door sensors

The EMCU-1-1B assures network managers that environmental conditions are within dened tolerances and that unauthorized entry into the equipment cabinets does not go unnoticed.

The EMCU-1-1B can be located in data centers, co-lo sites, web hosting facilities, telecom switching sites, POP sites, server closets, and any unmanned area that needs to be monitored. Install the EMCU-1-1B in the equipment cabinet and gain access to environmental conditions from a web or serial interface through one of Server Technology’s IP address-able CDUs.

  •  Each EMCU-1-1B is accessible via IP through networked CDU
  •  HTML GUI, Telnet or SNMP management
  •  Cabinet Environment Status: Supports two dual-function temperature & humidity probes (% RH)
         Water & fluid detection sensor
  •  Cabinet Intrusion Detection: Supports four dry contact closure door sensors
  •  Analog Input Sensor: Supports supplementary sensor requiring power feed
  •  Notication Warnings: SNMP and e-mail alerts through CDUs interface
  •  Thresholds & SNMP Traps to two destinations
  •  IP Management through Sentry CDUs  HTML Web Interface, Command Line Interface,  No additional software required
  •  Mounting
  •      Flexible zero U mounting
         Fast installation -- 5 minutes or less
  •  Warranty:2 years
Model Description Mounting
EMCU-1-1B
Environmental Monitor Control Unit with (1) combination
Temperature & Humidity Probe 10ft (3m) 
Mounting tabs included for zero U mounting
EMTH-1-1 Temperature & Humidity Probe 10ft (3m)  --
EMWS-1-1 Water Sensor Probe, 12 in. (305 mm) detection cable, 10 ft (3 m) connection cord   --

Part Code:

EMTH-1-1

Grade 
02/23/2016

Good experience

Product is good, good packaging, on-time delivered.

Write your review! !

Write a review

Server Technology EMTH-1-1 Environmental Monitor Control Unit

Server Technology EMTH-1-1 Environmental Monitor Control Unit

Ever increasing densities of vertically racked servers conserve valuable door space in the data center, but the resulting power consumption and heat dissipation create new concerns for data center managers.  Environmental Monitoring, particularly temperature & humidity, is a must for any sensitive infrastructure. The most recent ASHRAE thermal guidelines suggests three measurement points in the equipment rack.